DOM MB Diagnosis page

Board ID:

V5.0L 000111

Source:

From inspection, July, 2004

Symptoms:                            

Questionable drilling in via stack

Analyst(s):

G. Przybylski

Analysis Procedure(s):

Examination the questionable via. 
Loaded CPLD; Loaded EPC8; Loaded flash; Ran room temperature STF suite.
Ran low temperature profile.
LC Loopback failure at and below -60°C
At -70°C, the board fails many ATWD tests, and eventually crashes.

Root cause:

  Mistargeted drilling, or dull drill.

Mitigation:

Increased inspection, and more frequent drill replacement, since June.

Disposition:

The questionable via fails the minimum Class II via requirements.  (180° outside the pad)
This board should NOT be deployed.

Any Other Information:

Travler September 10

The via