DOM MB V5 Diagnosis page

Board ID:

V5 000131

Source:

Michael Harris

Symptoms:                    

7/2 (problem report crossed out) Failed to connect
7/23 'Same problem & the current fluctuates too much [30,50]'
9/24 ATWD A Most tests fail
11/05 boot problem reported

Analyst(s):

Thorsten Stezelberger/G. Przybylski

Analysis Procedure(s):

7/2 C112 looks damaned.  Power supply voltages low
7/13 5V output low.  U23 warm.  U23 installed backwards.
9/24 apparently no analysis.  See 11/5
11/05 boot problem not observed. Did observe ATWD A pulse failures traced to slow starting ATWD

Root cause:

7/2 Replaced C112  by loading vendor. Trouble sheet never finished off.
7/23 Faulty loading by vendor
11/05 Replace ATWD B and mainstream

Mitigation:

Replace mismounted U23
Replaced damaged C112
Reduce bad ATWD

Disposition:

Test, and mainstream

Any Other Information:


Traveler July 2
Traveler July 11
Traveler September 24
Traveler November 5
Parts