V5.0 - 00137 Non-Delivered July 2 , 2004
Source:
Naprotek, June 23, 2004
Symptoms:
Probing after reflow identified open between JP9-18 and R95-6.
Naprotek technician confirmed open circuit.
Analyst(s):
Przybylski
Analysis Procedure(s), Findings:
With an ohm meter, confirmed open ckt between U50.Y20 and R441.3.
No other vias on the way.
This is a non critical function, an R-2R ladder input for a
pulser we don't generally use.
With ohm-meter, confirmed open U35-45 to U50.H14. There is
a via in between, with continuity to U35.
The open circuit is at the U54 side. When running a flash
download, no activity can be seen at the via under U50.
Root cause:
Possibly faulty drilling or PTH plating plating under EPXA4.
Mitigation:
TBD
If the BGA is removed, the via under it can be tested from both
sides. If the via is OK, the board is recoverable by replacing
the EPXA4 with a new one. Otherwise, the board may be
unrecoverable without resorting to extraordinary measures, like
routing a green wire out under the BGA before remounting it.
Disposition:
Awaiting further review by vendor.
Any Other Information:
none