DOM MB Diagnosis page
Board ID:
Rev 5.0 SN 0168, from builder N,
and PCB manufacturer D
Source:
Non-delivered. Sent to LBL
as a non-conforming board.
Symptoms:
Anomalous probe station readings
around U8, the switching power supply chip
Analyst(s):
G. Przybylski
Analysis Procedure(s):
Disconnect switching power supply
output beads to allow measurements without endangering other components.
Measure power supply voltages unloaded. All OK.
Reconnect beads. Power up. All voltages OK.
Root cause:
Unknown
Mitigation:
Power up, and test all power
supply voltages and currents. Looks OK.
Disposition:
Reroute back to loading house for
hand work and normal delivery as a production board
Any Other Information:
none