DOM MB Diagnosis page

Board ID:

Rev 5.0 SN 0232

Source:

From STF testing crew

Symptoms:                            

Fails Local Coincidence Loopback tests

Analyst(s):

G. Przybylski

Analysis Procedure(s):

Test with terminations on both transformer outputs.  Run both LC transmitters with pulse outputs of both polarities.
Transmit signal into Z2 looks normal, however Receive signal from Z2 looks distorted (instead of absent)
Recommend removal and testing of Z2,  and checking for shorts on the board. 
Lifted lead of T3 and substituted 75 ohm load on output of Z2.  Waveforms now OK.  T3 must be bad.

Root cause:

Defective T3 MUB510D

Mitigation:

Disposition:

Sent to Helen for part removal.
Send to Helen for T3 replacement 9/3/04

Any Other Information:

Travler