DOM MB V5 Diagnosis
page
Board ID:
V5 000412
Source:
Azriel Goldschmidt
Symptoms:
At low temperatures, fails ATWD A Ch 2 Baseline test
Analyst(s):
G. Przybylski
Analysis Procedure(s):
Attempt to improve performance by DI water wash, followed by hot
air dry with heat gun.
During heating, discovered Oscillator ceased to function. Replaced
Corning B301538-01150 0429 with B301507-03018 0430
Profile at low temperatures. See traveler
Map out low temperature performance profile from -40°C to -75°C
Root cause:
Mitigation:
None
Disposition:
Pass by fiat, after collecting cold performance data.
Route to Europe only to insure that it cannot be assembled into an
IceTop DOM.
Any Other Information:
Traveler August 31