DOM MB V5 Diagnosis
page
Board ID:
V5 000492
Source:
Michael Harris
Symptoms:
In STF 2, Massive Chip A and B failures. fADC failures. Disc- Scan
Failures.
Analyst(s):
G. Przybylski
Analysis Procedure(s):
Pulser control voltage, and Trigger OK. ATWD Ch1 and Ch2 input
pedestal voltages OK, but ATWD Ch 0 pedestal voltage reads 2.65V
instead of 2.35. Traced to leaky CR26.
Root cause:
Faulty, or overheated Schottky diode.
Mitigation:
Replace faulty defective part.
Disposition:
Test, and mainstream
Any Other Information:
Traveler