DOM MB Diagnosis page
Board ID:
Rev 5.0 SN 000538
Source:
LED Testing; integration step
Symptoms:
Light pulse count lower than
expected
Analyst(s):
G. Przybylski
Analysis Procedure(s):
Tested LED power circuit: ledon/ledmax/ledmin. Seems normal.
Root cause:
Apparently software event counting
bug has been fixed.
Mitigation:
None
Disposition:
Route back to integration
testing for retest; Mainstream
Any Other Information:
Traveler