DOM MB V5.1 Diagnosis
page
Board ID:
V5.1 001145
Step:
Vendor STF Test
Symptoms:
March 22, 2005, Pressure reading incorrect
Analyst(s):
G. Przybylski
Analysis Procedure(s):
5/4/05: Probed U1-4 while grounding U1-8. Reading is 2.89V
instead of the expected ~4.0V.
Root cause:
Faulty U1.
Mitigation:
Replace, retest and mainstream
Disposition:
Repair pending 3/4/05
Any Other Information:
Traveler March 22, 2005